C-TEC-FF504-C-TEC
Item No. 38020
The C-TEC-FF504-C-TEC MFP 4 Zone Conventional Fire Alarm Panel is a microprocessor-based device designed for robust performance. It features a durable metal enclosure with a lift-off lid and heavy-duty base connections. This panel supports 4 conventional zone circuits, expandable to 12, and 4
Out of stock
Description
The C-TEC-FF504-C-TEC MFP 4 Zone Conventional Fire Alarm Panel is a microprocessor-based device designed for robust performance. It features a durable metal enclosure with a lift-off lid and heavy-duty base connections. This panel supports 4 conventional zone circuits, expandable to 12, and 4 conventional sounder circuits. It includes separate indicators for open circuit, short circuit, head-out, sounder, and battery/power supply faults. The panel offers a non-latching class change sounder input, latching fire, and non-latching fault outputs via an expansion loom. It also provides a zone-selectable short circuit=fire facility (pre-1980 BS, no resistors in call points). The panel can support up to 8 two-wire repeaters per main panel and is available in multi-lingual variants (subject to quantities). It has space for 2 x 12V 3.2Ah VRLA batteries and is compatible with virtually all known conventional fire detectors, including C-TEC’s ActiV range. Designed to comply with BS 5839-4, this panel is not compliant with EN54-2/4 and should not be used in new UK or European installations.
- Microprocessor based design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 4 conventional Zone circuits (expandable to 12).
- 4 conventional Sounder circuits.
- Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults.
- Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).
- Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
- Up to 8 two-wire Repeaters per Main panel.
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Specifications
- Product Code
- C-TEC-FF504-C-TEC
- Manufacturer
- C-Tec
- Colour
- White
- Connection
- Wired
- Depth
- 92mm
- Height
- 267mm
- Mounting
- Wall
- Product Type
- Fire Panel
- System Type
- Conventional
- Width
- 405mm
- Zones
- 4
C-TEC-FF504-C-TEC
Item No. 38020
The C-TEC-FF504-C-TEC MFP 4 Zone Conventional Fire Alarm Panel is a microprocessor-based device designed for robust performance. It features a durable metal enclosure with a lift-off lid and heavy-duty base connections. This panel supports 4 conventional zone circuits, expandable to 12, and 4
Out of stock
Description
The C-TEC-FF504-C-TEC MFP 4 Zone Conventional Fire Alarm Panel is a microprocessor-based device designed for robust performance. It features a durable metal enclosure with a lift-off lid and heavy-duty base connections. This panel supports 4 conventional zone circuits, expandable to 12, and 4 conventional sounder circuits. It includes separate indicators for open circuit, short circuit, head-out, sounder, and battery/power supply faults. The panel offers a non-latching class change sounder input, latching fire, and non-latching fault outputs via an expansion loom. It also provides a zone-selectable short circuit=fire facility (pre-1980 BS, no resistors in call points). The panel can support up to 8 two-wire repeaters per main panel and is available in multi-lingual variants (subject to quantities). It has space for 2 x 12V 3.2Ah VRLA batteries and is compatible with virtually all known conventional fire detectors, including C-TEC’s ActiV range. Designed to comply with BS 5839-4, this panel is not compliant with EN54-2/4 and should not be used in new UK or European installations.
- Microprocessor based design.
- Robust metal enclosure c/w lift off lid & heavy-duty base connections.
- 4 conventional Zone circuits (expandable to 12).
- 4 conventional Sounder circuits.
- Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults.
- Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).
- Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
- Up to 8 two-wire Repeaters per Main panel.
- Multi-lingual variants (subject to quantities).
- Space for 2 x 12V 3.2Ah VRLA batteries.
- Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.
- Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations).
Specifications
- Product Code
- C-TEC-FF504-C-TEC
- Manufacturer
- C-Tec
- Colour
- White
- Connection
- Wired
- Depth
- 92mm
- Height
- 267mm
- Mounting
- Wall
- Product Type
- Fire Panel
- System Type
- Conventional
- Width
- 405mm
- Zones
- 4