C-TEC-FF502P
Item No. 38010
The C-TEC-FF502P is a 4-zone sounder circuit extender kit that provides four additional conventional sounder circuits with open and short circuit fault monitoring. Compatible with most manufacturers’ fire alarm control panels, it is supplied on a double gang plate. Basic connection requires four
In stock
Description
The C-TEC-FF502P is a 4-zone sounder circuit extender kit that provides four additional conventional sounder circuits with open and short circuit fault monitoring. Compatible with most manufacturers’ fire alarm control panels, it is supplied on a double gang plate. Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve, and Sounder +Ve. These can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or an external PSU. When connecting to a C-TEC fire panel, only three input control wires are required (Sounder –Ve is not needed as C-TEC conventional panels have a common 0V rail). The kit fits on standard UK 25mm flush or surface mount back boxes.
- Provides four extra conventional sounder circuits with open and short circuit fault monitoring.
- Compatible with most manufacturers’ fire alarm control panels.
- Supplied on a double gang plate.
- Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve.
- Sounder -Ve & Sounder +Ve can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or, alternatively, from an external PSU.
- If connecting the FF502P to a C-TEC fire panel only three input control wires are required (Sounder -Ve is not required as our conventional panels have a common 0V rail).
- Fits on standard UK 25mm flush or surface mount back boxes.
Specifications
- Product Code
- C-TEC-FF502P
- Manufacturer
- C-Tec
- Connection
- Wired
- Product Type
- Relay
- Zones
- 4
C-TEC-FF502P
Item No. 38010
The C-TEC-FF502P is a 4-zone sounder circuit extender kit that provides four additional conventional sounder circuits with open and short circuit fault monitoring. Compatible with most manufacturers’ fire alarm control panels, it is supplied on a double gang plate. Basic connection requires four
In stock
Description
The C-TEC-FF502P is a 4-zone sounder circuit extender kit that provides four additional conventional sounder circuits with open and short circuit fault monitoring. Compatible with most manufacturers’ fire alarm control panels, it is supplied on a double gang plate. Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve, and Sounder +Ve. These can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or an external PSU. When connecting to a C-TEC fire panel, only three input control wires are required (Sounder –Ve is not needed as C-TEC conventional panels have a common 0V rail). The kit fits on standard UK 25mm flush or surface mount back boxes.
- Provides four extra conventional sounder circuits with open and short circuit fault monitoring.
- Compatible with most manufacturers’ fire alarm control panels.
- Supplied on a double gang plate.
- Basic connection requires four wires: 24 VDC, 0V, Sounder –Ve & Sounder +Ve.
- Sounder -Ve & Sounder +Ve can be connected at the host panel or any convenient point on a sounder circuit (DO NOT SPUR). 24 VDC and 0V can be derived from the host panel or, alternatively, from an external PSU.
- If connecting the FF502P to a C-TEC fire panel only three input control wires are required (Sounder -Ve is not required as our conventional panels have a common 0V rail).
- Fits on standard UK 25mm flush or surface mount back boxes.
Specifications
- Product Code
- C-TEC-FF502P
- Manufacturer
- C-Tec
- Connection
- Wired
- Product Type
- Relay
- Zones
- 4